ORIGINAL ARTICLES
Simulation of the 6 MV Elekta Synergy Platform linac photon beam using Geant4 Application for Tomographic Emission
Samir Didi, Abdelilah Moussa, Tayalati Yahya, Zerfaoui Mustafa
July-September 2015, 40(3):136-143
DOI
:10.4103/0971-6203.165077
PMID
:26500399
The present work validates the Geant4 Application for Tomographic Emission Monte Carlo software for the simulation of a 6 MV photon beam given by Elekta Synergy Platform medical linear accelerator treatment head. The simulation includes the major components of the linear accelerator (LINAC) with multi-leaf collimator and a homogeneous water phantom. Calculations were performed for the photon beam with several treatment field sizes ranging from 5 cm × 5 cm to 30 cm × 30 cm at 100 cm distance from the source. The simulation was successfully validated by comparison with experimental distributions. Good agreement between simulations and measurements was observed, with dose differences of about 0.02% and 2.5% for depth doses and lateral dose profiles, respectively. This agreement was also emphasized by the Kolmogorov–Smirnov goodness-of-fit test and by the gamma-index comparisons where more than 99% of the points for all simulations fulfill the quality assurance criteria of 2 mm/2%.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
4
6,561
396
Production, biodistribution, and dosimetry of
47
Sc-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylene phosphonic acid as a bone-seeking radiopharmaceutical
Fatemeh Fathi, Leila Moghaddam-Banaem, Mojtaba Shamsaei, Ali Samani, Mohammad G Maragheh
July-September 2015, 40(3):156-164
DOI
:10.4103/0971-6203.165078
PMID
:26500402
In this study 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylene phosphonic acid (DOTMP) was used as the polyaminophosphonic acid carrier ligand and the therapeutic potential of the bone seeking radiopharmaceutical
47
Sc-DOTMP was assessed by measuring its dosage–dependent skeletal uptake and then the absorbed radiation dose of human organs was estimated. Because of limited availability of
47
Sc we performed some preliminary studies using
46
Sc.
46
Sc was produced with a specific activity of 116.58 MBq/mg (3.15 mCi/mg) and radionuclide purity of 98%.
46
Sc-DOTMP was prepared and an activity of 1.258 MBq (34 μCi) at a chelant-to-metal ratio of 60:1 was administered to five groups of mice with each group containing 3 mice that were euthanized at 4, 24, 48, 96 and 192 h post administration. The heart, lungs, liver, spleen, kidneys, intestine, skin, muscle, and a femur were excised, weighed, and counted. The data were analyzed to determine skeletal uptake and source organ residence times and cumulated activities for
47
Sc-DOTMP.
46
Sc-DOTMP complex was prepared in radiochemical purity about 93%.
In vitro
stability of complex was evaluated at room temperature for 48 h. Biodistribution studies of complex in mice were studied for 7 days. The data were analyzed to estimate skeletal uptake and absorbed radiation dose of human organs using biodistribution data from mice. By considering the results,
47
Sc-DOTMP is a possible therapeutic agent for using in palliation of bone pain due to metastatic skeletal lesions from several types of primary cancers in prostate, breast, etc.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
4
2,614
225
Performance characteristics of mobile MOSFET dosimeter for kilovoltage X-rays used in image guided radiotherapy
A Sathish Kumar, I Rabi Raja Singh, SD Sharma, B Paul Ravindran
July-September 2015, 40(3):123-128
DOI
:10.4103/0971-6203.165074
PMID
:26500397
The main objective of this study was to investigate the characteristics of metal oxide semiconductor field effect transistor (MOSFET) dosimeter for kilovoltage (kV) X-ray beams in order to perform the
in vivo
dosimetry during image guidance in radiotherapy. The performance characteristics of high sensitivity MOSFET dosimeters were investigated for 80, 90, 100, 110, 120, and 125 kV X-ray beams used for imaging in radiotherapy. This study was performed using Clinac 2100 C/D medical electron linear accelerator with on-board imaging and kV cone beam computed tomography system. The characteristics studied in this work include energy dependence, angular dependence, and linearity. The X-ray beam outputs were measured as per American Association of Physicists in Medicine (AAPM) TG 61 recommendations using PTW parallel plate (PP) ionization chamber, which was calibrated in terms of air kerma (Nk) by the National Standard Laboratory. The MOSFET dosimeters were calibrated against the PP ionization chamber for all the kV X-ray beams and the calibration coefficient was found to be 0.11 cGy/mV with a standard deviation of about ±1%. The response of MOSFET was found to be energy independent for the kV X-ray energies used in this study. The response of the MOSFET dosimeter was also found independent of angle of incidence for the gantry angles in the range of 0° to 360° in-air as well as at 3 cm depth in tissue equivalent phantom.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
3
3,019
266
LETTER TO EDITOR
Three-dimensional polymer gel dosimetry using an onboard 0.35 T magnetic resonance imaging scanner: A simulation study
Lei Zhang, Yanle Hu, Dongsu Du, Olga L Green, H Omar Wooten, H Harold Li
July-September 2015, 40(3):176-180
DOI
:10.4103/0971-6203.165081
PMID
:26500405
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
2
2,481
205
ORIGINAL ARTICLES
Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery
S Timothy Peace Balasingh, I Rabi Raja Singh, K Mohamathu Rafic, S Ebenezer Suman Babu, B Paul Ravindran
July-September 2015, 40(3):129-135
DOI
:10.4103/0971-6203.165072
PMID
:26500398
As complex treatment techniques such as intensity modulated radiotherapy (IMRT) entail the modeling of rounded leaf-end transmission in the treatment planning system, it is important to accurately determine the dosimetric leaf gap (DLG) value for a precise calculation of dose. The advancements in the application of the electronic portal imaging device (EPID) in quality assurance (QA) and dosimetry have facilitated the determination of DLG in this study. The DLG measurements were performed using both the ionization chamber (DLG
ion
) and EPID (DLG
EPID
) for sweeping gap fields of different widths. The DLG
ion
values were found to be 1.133 mm and 1.120 mm for perpendicular and parallel orientations of the 0.125 cm
3
ionization chamber, while the corresponding DLG
EPID
values were 0.843 mm and 0.819 mm, respectively. It was found that the DLG was independent of volume and orientation of the ionization chamber, depth, source to surface distance (SSD), and the rate of dose delivery. Since the patient-specific QA tests showed comparable results between the IMRT plans based on the DLG
EPID
and DLG
ion
, it is concluded that the EPID can be a suitable alternative in the determination of DLG.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
6,697
476
Radiobiological evaluation of intensity modulated radiation therapy treatments of patients with head and neck cancer: A dual-institutional study
G Narayanasamy, AP Pyakuryal, S Pandit, J Vincent, C Lee, P Mavroidis, N Papanikolaou, M Kudrimoti, TT Sio
July-September 2015, 40(3):165-169
DOI
:10.4103/0971-6203.165075
PMID
:26500403
In clinical practice, evaluation of clinical efficacy of treatment planning stems from the radiation oncologist's experience in accurately targeting tumors, while keeping minimal toxicity to various organs at risk (OAR) involved. A more objective, quantitative method may be raised by using radiobiological models. The purpose of this work is to evaluate the potential correlation of OAR-related toxicities to its radiobiologically estimated parameters in simultaneously integrated boost (SIB) intensity modulated radiation therapy (IMRT) plans of patients with head and neck tumors at two institutions. Lyman model for normal tissue complication probability (NTCP) and the Poisson model for tumor control probability (TCP) models were used in the Histogram Analysis in Radiation Therapy (HART) analysis. In this study, 33 patients with oropharyngeal primaries in the head and neck region were used to establish the correlation between NTCP values of (a) bilateral parotids with clinically observed rates of xerostomia, (b) esophagus with dysphagia, and (c) larynx with dysphagia. The results of the study indicated a strong correlation between the severity of xerostomia and dysphagia with Lyman NTCP of bilateral parotids and esophagus, respectively, but not with the larynx. In patients without complications, NTCP values of these organs were negligible. Using appropriate radiobiological models, the presence of a moderate to strong correlation between the severities of complications with NTCP of selected OARs suggested that the clinical outcome could be estimated prior to treatment.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
2,881
200
Monte carlo dose calculation in dental amalgam phantom
Mohd Zahri Abdul Aziz, AL Yusoff, ND Osman, R Abdullah, NA Rabaie, MS Salikin
July-September 2015, 40(3):150-155
DOI
:10.4103/0971-6203.165080
PMID
:26500401
It has become a great challenge in the modern radiation treatment to ensure the accuracy of treatment delivery in electron beam therapy. Tissue inhomogeneity has become one of the factors for accurate dose calculation, and this requires complex algorithm calculation like Monte Carlo (MC). On the other hand, computed tomography (CT) images used in treatment planning system need to be trustful as they are the input in radiotherapy treatment. However, with the presence of metal amalgam in treatment volume, the CT images input showed prominent streak artefact, thus, contributed sources of error. Hence, metal amalgam phantom often creates streak artifacts, which cause an error in the dose calculation. Thus, a streak artifact reduction technique was applied to correct the images, and as a result, better images were observed in terms of structure delineation and density assigning. Furthermore, the amalgam density data were corrected to provide amalgam voxel with accurate density value. As for the errors of dose uncertainties due to metal amalgam, they were reduced from 46% to as low as 2% at d
80
(depth of the 80% dose beyond Z
max
) using the presented strategies. Considering the number of vital and radiosensitive organs in the head and the neck regions, this correction strategy is suggested in reducing calculation uncertainties through MC calculation.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
1
2,587
247
EDITORIAL
Demand and supply of medical physicists: Issues of quantity, quality, and competency in India
SD Sharma
July-September 2015, 40(3):121-122
DOI
:10.4103/0971-6203.165079
PMID
:26500396
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
3,298
230
ORIGINAL ARTICLES
A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams
KR Muralidhar, Suresh Pangam, P Srinivas, Mirza Athar Ali, V Sujana Priya, Krishna Komanduri
July-September 2015, 40(3):144-149
DOI
:10.4103/0971-6203.165076
PMID
:26500400
To study the behavior of Acuros XB algorithm for flattening filter free (FFF) photon beams in comparison with the anisotropic analytical algorithm (AAA) when applied to homogeneous and heterogeneous phantoms in conventional and RapidArc techniques. Acuros XB (Eclipse version 10.0, Varian Medical Systems, CA, USA) and AAA algorithms were used to calculate dose distributions for both 6X FFF and 10X FFF energies. RapidArc plans were created on Catphan phantom 504 and conventional plans on virtual homogeneous water phantom 30 × 30 × 30 cm
3
, virtual heterogeneous phantom with various inserts and on solid water phantom with air cavity. Dose at various inserts with different densities were measured in both AAA and Acuros algorithms. The maximum % variation in dose was observed in (−944 HU) air insert and minimum in (85 HU) acrylic insert in both 6X FFF and 10X FFF photons. Less than 1% variation observed between −149 HU and 282 HU for both energies. At −40 HU and 765 HU Acuros behaved quite contrarily with 10X FFF. Maximum % variation in dose was observed in less HU values and minimum variation in higher HU values for both FFF energies. Global maximum dose observed at higher depths for Acuros for both energies compared with AAA. Increase in dose was observed with Acuros algorithm in almost all densities and decrease at few densities ranging from 282 to 643 HU values. Field size, depth, beam energy, and material density influenced the dose difference between two algorithms.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
3,349
301
TECHNICAL NOTE
Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
A Saravanakumar, K Vaideki, KN Govindarajan, S Jayakumar, B Devanand
July-September 2015, 40(3):170-175
DOI
:10.4103/0971-6203.165073
PMID
:26500404
In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDI
w
) and in turn the volumetric CTDI (CTDI
v
) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDI
v
measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[PubMed]
-
2,715
235
Search this journal
Advance Search
Editorial Board
The Journal
The Association
Alerting
Feedback
Contact Us
Contact us
|
Sitemap
|
Advertise
|
What's New
|
Copyright and Disclaimer
|
Privacy Notice
© 2006 - Journal of Medical Physics | Published by Wolters Kluwer -
Medknow
Online since 10
th
April, 2006