Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Reader Login The official journal of AMPI, IOMP and AFOMP      
 Users online: 837  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
  Citation statistics : Table of Contents
   2015| January-March  | Volume 40 | Issue 1  
    Online since February 27, 2015

 
 
  Archives   Previous Issue   Next Issue   Most popular articles   Most cited articles
 
Show all abstracts  Show selected abstracts  Export selected to
  Cited Viewed PDF
ORIGINAL ARTICLES
Up-regulation of Bcl-2 expression in cultured human lymphocytes after exposure to low doses of gamma radiation
Hosein Azimian, Mohammad Taghi Bahreyni-Toossi, Abdul Rahim Rezaei, Houshang Rafatpanah, Tayebeh Hamzehloei, Reza Fardid
January-March 2015, 40(1):38-44
DOI:10.4103/0971-6203.152249  PMID:26150686
  11 4,627 170
Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system
Reena Sharma, Sunil Dutt Sharma, Shramika Pawar, Ajay Chaubey, S Kantharia, D A R Babu
January-March 2015, 40(1):29-37
DOI:10.4103/0971-6203.152244  PMID:26150685
  10 14,065 675
TECHNICAL NOTES
Radiological health assessment of natural radioactivity in the vicinity of Obajana cement factory, North Central Nigeria
Omoniyi Matthew Isinkaye, Nnamdi N Jibiri, Adebowale A Olomide
January-March 2015, 40(1):52-59
DOI:10.4103/0971-6203.152256  PMID:26150688
  5 2,331 217
ORIGINAL ARTICLES
Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose
Roshan S Livingstone, David Chase, Anna Varghese, Paul V George, Oommen K George
January-March 2015, 40(1):24-28
DOI:10.4103/0971-6203.152241  PMID:26150684
  2 2,504 217
What benefit could be derived from on-line adaptive prostate radiotherapy using rectal diameter as a predictor of motion?
Richard Oates, Suki Gill, Farshad Foroudi, Michael Lim Joon, Michal Schneider, Mathias Bressel, Tomas Kron
January-March 2015, 40(1):18-23
DOI:10.4103/0971-6203.152237  PMID:26150683
  1 2,187 184
TECHNICAL NOTES
Effect of anode/filter combination on average glandular dose in mammography
Michal Biegala, Teresa Jakubowska, Karolina Markowska
January-March 2015, 40(1):45-51
DOI:10.4103/0971-6203.152251  PMID:26150687
  1 3,223 273
EDITORIAL
IMRT, IGRT, and other high technology becomes standard in external beam radiotherapy: But is image-guided brachytherapy for cervical cancer too expensive?
Jamema V Swamidas, Christian Kirisits
January-March 2015, 40(1):1-4
DOI:10.4103/0971-6203.152229  PMID:26150680
  - 1,914 215
ORIGINAL ARTICLES
Monte Carlo-based dose calculation for 32 P patch source for superficial brachytherapy applications
Sridhar Sahoo, Selvam T Palani, SK Saxena, D A R Babu, A Dash
January-March 2015, 40(1):13-17
DOI:10.4103/0971-6203.152232  PMID:26150682
  - 2,935 293
A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files
Juan Agustin Calama Santiago, Miguel Angel Infante Utrilla, Maria Elisa Lavado Rodriguez
January-March 2015, 40(1):5-12
DOI:10.4103/0971-6203.152231  PMID:26150681
  - 2,736 272
 
  Search this journal
    
  Advance Search
 
  Editorial Board 
  The Journal 
  The Association 
  Alerting 
  Feedback 
  Contact Us