Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 452  Home  EMail this page Print this page Decrease font size Default font size Increase font size 

    Article Cited by others

ORIGINAL ARTICLE

Dosimetry and verification of 60Co total body irradiation with human phantom and semiconductor diodes

Allahverdi Mahmoud, Geraily Ghazale, Esfehani Mahbod, Sharafi Aliakbar, Haddad Peyman, Shirazi Alireza

Year : 2007| Volume: 32| Issue : 4 | Page no: 169-174

   This article has been cited by
 
1 Dosimetric comparison of AP/PA and bilateral geometries for total body irradiation treatment
Elham Hoseinnezhad Zarghani, Ghazale Geraily, Peiman Haddad, Mahbod Esfahani, Mostafa Farzin, Ali Rastjoo, Mohammad Kazem Amini
Radiation and Environmental Biophysics. 2021; 60(4): 663
[Pubmed]  [Google Scholar] [DOI]
2 Comparison of different TBI techniques in terms of dose homogeneity – review study
E. Hoseinnezhad Zarghani, G. Geraily, T. Hadisinia
Cancer/Radiothérapie. 2021; 25(4): 380
[Pubmed]  [Google Scholar] [DOI]
3 Comparison of calculated and measured basic dosimetric parameters for total body irradiation with 6- and 18-MV photon beams
Elham Hoseinnezhad, Ghazale Geraily, Mahbod Esfahani, Mostafa Farzin, Somayeh Gholami
Journal of Radiotherapy in Practice. 2021; 20(1): 66
[Pubmed]  [Google Scholar] [DOI]
4 Evaluation of the surface dose for total body irradiation (TBI) technique with parallel-opposed anterior posterior geometry
Hoseinnezhadzarghani Elham, Geraily Ghazale, Sarvin Sarmadi
Journal of Radiotherapy in Practice. 2021; : 1
[Pubmed]  [Google Scholar] [DOI]
5 A method to improve the accuracy of diode in vivo dosimetry for external megavoltage photon beams filtered by wedges
Alireza Mohammadkarim,Mahmoud Allahverdi,Hasanali Nedaie,Mahbod Esfehani,Alireza Shirazi,Ghazale Geraily
Journal of Theoretical and Applied Physics. 2013; 7(1): 13
[Pubmed]  [Google Scholar] [DOI]
6 Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy
Allahverdi, M., Mohammadkarim, A., Esfehani, M., Nedaie, H., Shirazi, A., Geraily, G.
Journal of Medical Physics. 2012; 37(1): 32-39
[Pubmed]  [Google Scholar]
7 Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI)
Ramamoorthy Ravichandran, Johnson Pichi Binukumar, Chirayathmanjiyil Antony Davis, Somangali Sathiyamurthy Sivakumar, Kammari Krishnamurthy, Zahid Al Mandhari, Balakrishnan Rajan
Physica Medica. 2011; 27(3): 163
[HTML Full text]  [Google Scholar] [DOI]

 

Read this article