Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 65  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
TECHNICAL NOTE
Year : 2022  |  Volume : 47  |  Issue : 3  |  Page : 301-308

Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo


1 Medical Radiation Programme, School of Health Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
2 Department of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, 13200 Kepala Batas, Pulau Pinang, Malaysia

Correspondence Address:
Dr. J Jayamani
Medical Radiation Programme, School of Health Sciences, Universiti Sains Malaysia, Health Campus, 16150 Kubang Kerian, Kelantan
Malaysia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.jmp_40_22

Rights and Permissions

Accuracy of ionization chamber (IC) to measure the scatter output factor (Scp) of a linear accelerator (linac) is crucial, especially in small field (<4 cm × 4 cm). The common IC volume of 0.6 cc is not adequate for small-field measurement and not all radiotherapy centers can afford to purchase additional IC due to the additional cost. This study aimed to determine the efficiency of the EGSnrc Monte Carlo (MC) to calculate the Scp for various field sizes including small field in Elekta Synergy (Agility multileaf collimator) linac. The BEAMnrc and DOSXYZnrc user codes were used to simulate a 6 MV linac model for various field sizes and calculate the radiation dose output in water phantom. The modeled linac treatment head was validated by comparing the percentage depth dose (PDD), beam profile, and beam quality (Tissue Phantom Ratio (TPR)20,10) with the IC measurement. The validated linac model was simulated to calculate the Scp consisting of collimator scatter factor (Sc) and phantom scatter factor (Sp). The PDD and beam profile of the simulated field sizes were within a good agreement of ±2% compared with the measured data. The TPR20,10 value was 0.675 for field size 10 cm × 10 cm. The Scp, Sc, and Sp simulated values were close to the IC measurement within ±2% difference. The simulation for Sc and Sp in 3 cm × 3 cm field size was calculated to be 0.955 and 0.884, respectively. In conclusion, this study validated the efficiency of the MC simulation as a promising tool for the Scp calculation including small-field size for linac.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed190    
    Printed4    
    Emailed0    
    PDF Downloaded43    
    Comments [Add]    

Recommend this journal