Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 1060  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 47  |  Issue : 3  |  Page : 270-278

Monte carlo study on dose distributions around 192Ir, 169Yb, and 125I brachytherapy sources using EGSnrc-based egs_brachy user-code


1 Division of Radiological Physics and Advisory, Health Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
2 Division of Radiological Safety, Atomic Energy Regulatory Board, Mumbai, Maharashtra, India
3 Division of Radiological Physics and Advisory, Health Safety and Environment Group, Bhabha Atomic Research Centre; Homi Bhabha National Institute, Mumbai, Maharashtra, India
4 Department of Radiation Oncology, P. D. Hinduja National Hospital and MRC, Mumbai, Maharashtra, India

Correspondence Address:
Dr. Subhalaxmi Mishra
Division of Radiological Physics and Advisory, Health Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai - 400 094, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.jmp_16_22

Rights and Permissions

Introduction/: As per the recommendations of the American Association of Physicists in Medicine Task Group 43, Monte Carlo (MC) investigators should reproduce previously published dose distributions whenever new features of the code are explored. The purpose of the present study is to benchmark the TG-43 dosimetric parameters calculated using the new MC user-code egs_brachy of EGSnrc code system for three different radionuclides 192Ir, 169Yb, and 125I which represent high-, intermediate-, and low-energy sources, respectively. Materials and Methods: Brachytherapy sources investigated in this study are high-dose rate (HDR) 192Ir VariSource (Model VS2000), 169Yb HDR (Model 4140), and 125I -low-dose-rate (LDR) (Model OcuProsta). The TG-43 dosimetric parameters such as air-kerma strength, Sk, dose rate constant, Λ, radial dose function, g(r) and anisotropy function, F(r,θ) and two-dimensional (2D) absorbed dose rate data (along-away table) are calculated in a cylindrical water phantom of mass density 0.998 g/cm3 using the MC code egs_brachy. Dimensions of phantom considered for 192Ir VS2000 and 169Yb sources are 80 cm diameter ×80 cm height, whereas for 125I OcuProsta source, 30 cm diameter ×30 cm height cylindrical water phantom is considered for MC calculations. Results: The dosimetric parameters calculated using egs_brachy are compared against the values published in the literature. The calculated values of dose rate constants from this study agree with the published values within statistical uncertainties for all investigated sources. Good agreement is found between the egs_brachy calculated radial dose functions, g(r), anisotropy functions, and 2D dose rate data with the published values (within 2%) for the same phantom dimensions. For 192Ir VS2000 source, difference of about 28% is observed in g(r) value at 18 cm from the source which is due to differences in the phantom dimensions. Conclusion: The study validates TG-43 dose parameters calculated using egs_brachy for 192Ir, 169Yb, and 125I brachytherapy sources with the values published in the literature.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed582    
    Printed24    
    Emailed0    
    PDF Downloaded134    
    Comments [Add]    

Recommend this journal