Evaluating the impact of ionization chamber-specific beam quality correction factor in dosimetry of filtered and unfiltered photon beams


1 Department of Applied Physics, Amity Institute of Applied Sciences, Amity University, Noida; Department of Medical Physics, Homi Bhabha Cancer Hospital, Varanasi, Uttar Pradesh, India
2 Bhabha Atomic Research Centre, Radiological Physics and Advisory Division, CTCRS, Mumbai, Maharashtra, India
3 Department of Medical Physics, Homi Bhabha Cancer Hospital, Varanasi, Uttar Pradesh, India
4 Department of Physics, School of Engineering, University of Petroleum and Energy Studies, Dehradun, Uttarakhand, India
5 Department of Applied Physics, Amity Institute of Applied Sciences, Amity University, Noida, Uttar Pradesh, India

Correspondence Address:
Mrs. Richa Sharma
Department of Applied Physics, Amity Institute of Applied Sciences, Amity University, Noida - 201 313, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.jmp_101_21

Rights and Permissions

Aim: The response of ionization chamber changes when used at beam quality Q which is different from beam quality Qo (usually 60Co) that was used at the time of its calibration. Hence, one needs to apply beam quality correction factor (kQ, Qo) during dosimetric measurements. However, kQ, Qo data are unavailable for novel ion chambers in the literature. Moreover, most of such data do not differentiate between filtered (flat) and unfiltered (unflat) beams. In addition, literature-based data do not differentiate among different pieces of the ion chambers of the same make and model. Hence, the purpose of our study was to determine the ion chamber-specific experimental values of kQ, Qo and to evaluate their impact in dosimetry. Materials and Methods: In this work, the value of kQ, Qo were measured for six ionization chambers of three different types in 6, 10, and 15 MV filtered (with flattening filter [WFF]) as well as 6 and 10 MV unfiltered (flattening filter free [FFF]) photon beams. The measured values of kQ, Qo were compared with Monte Carlo-calculated values available in the literature. The uncertainties in measurement of kQ, Qo values were also evaluated. Results: For 6 MV FFF beam, the measured value of kQ, Qo was found to be consistently lower than 6 MV WFF beam for all Sun Nuclear Corporation ion chambers, while it was higher as per the theoretical data. The inter-chamber variation in kQ, Qo values was observed for the same model of the ion chambers. The maximum difference between absolute dose values on using the theoretical and experimental kQ, Qo values was up to 3.23%. Conclusion: The measured absolute dose values by the ion chamber of a given make and model were found different due to the use of its theoretical and experimental kQ, Qo values. Furthermore, the variation in response of different pieces of ion chambers of the same make and model cannot be accounted for theoretically, and hence, the use of theoretical kQ, Qo data may introduce an inherent error in the estimation of absorbed dose to water. This necessitates the use of measured value of kQ, Qo for each ionization chamber.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed140    
    Printed2    
    Emailed0    
    PDF Downloaded52    
    Comments [Add]    

Recommend this journal