Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 1136  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 47  |  Issue : 1  |  Page : 34-39

Calculation of attenuation parameter for Ir-192 gamma source in shielding materials


1 School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Terengganu, Malaysia
2 Oncological and Radiological Science Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia
3 Department of Physics and Engineering Physics, Obafemi Awolowo University, Ile-Ife, Nigeria

Correspondence Address:
Dr. Adila Hanim Aminordin Sabri
Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Terengganu
Malaysia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.jmp_86_21

Rights and Permissions

Purpose: Calculation of photon attenuation is necessary for the selection of shielding materials for an irradiation facility. Methods and Materials: In this work, a Monte Carlo simulation was utilized to assess the effectiveness of clay-polyethylene mixture and clay as the radiation shielding materials for high-energy gamma sources (Ir-192). Ordinary concrete was also studied as the benchmark. Results: The calculated linear attenuation values for ordinary concrete are within 0.44% of the standard XCOM value for 380 keV photon. In the case of a multienergy Ir-192 gamma source, the calculated linear attenuation coefficient (μ) for ordinary concrete is 15.5% and 7.25% higher than clay and fabricated clay-polyethylene, respectively. Meanwhile, the μ value for fabricated clay-polyethylene is 8.3% higher than that of clay. Conclusion: In conclusion, a 10 cm thickness of clay and clay-polyethylene mixture is sufficient to attenuate 87% and 89% of photons from Ir-192 source. The calculated linear attenuation coefficients for the three shielding materials are also consistently higher, about 7.5%, than that of the XCOM value for 380 keV photon.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed256    
    Printed6    
    Emailed0    
    PDF Downloaded55    
    Comments [Add]    