Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 669  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2012  |  Volume : 37  |  Issue : 3  |  Page : 124-128

Dosimetric analysis of trigeminal nerve, brain stem doses in CyberKnife radiosurgery of trigeminal neuralgia


1 Department of Radiotherapy, Apollo Speciality Hospital, Chennai, India
2 Department of Medical Physics, Anna University, Chennai, India

Correspondence Address:
H Sudahar
Department of Radiotherapy, Apollo Speciality Hospital, 320, Padma complex, Mount Road, Chennai - 600 035, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-6203.99225

Rights and Permissions

CyberKnife radiosurgery treatment of Trigeminal neuralgia (TN) is performed as a non-invasive image guided procedure. The prescription dose for TN is very high. The brainstem is the adjacent critical organ at risk (OAR) which is prone to receive the very high target dose of TN. The present study is to analyze the dose distribution inside the tiny trigeminal nerve target and also to analyze the dose fall off in the brain stem. Seven TN cases treated between November 2010 and January 2012 were taken for this study retrospectively. The treatment plans were analyzed for target dose conformity, homogeneity and dose coverage. In the brainstem the volume doses D 1% , D 2% were taken for analyzing the higher doses in the brain stem. The dose fall off was analyzed in terms of D 5% and D 10%. The mean value of maximum dose within the trigeminal nerve target was 73.5± 2.1Gy (P=0.0007) and the minimum dose was 50.0±4.1Gy (P=0.1315). The mean conformity index was 2.19 and the probable reason could be the smallest CyberKnife collimator of 5mm used in the treatment plan. The mean D 1% , of the brainstem was 10.5± 2.1Gy (P=0.5316) and the mean value of the maximum point dose within the brainstem was 35.6±3.8Gy. This shows the degree of dose fall off within the brainstem. Though the results of the present study are showing superior sparing of brain stem and reasonable of target coverage, it is necessary to execute the treatment plan with greater accuracy in CyberKnife as the immobilization is noninvasive and frameless.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4336    
    Printed183    
    Emailed2    
    PDF Downloaded244    
    Comments [Add]    
    Cited by others 2    

Recommend this journal