Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 559  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2010  |  Volume : 35  |  Issue : 4  |  Page : 202-206

Effect of various physical parameters on surface and build-up dose for 15-MV X-rays


1 Department of Physics, D.A.V. (P.G.) College, Kanpur, U.P., India
2 Department of Medical Physics, AMRI Hospitals, Kolkata, India

Correspondence Address:
Girigesh Yadav
C/o Dr R. S. Yadav, 82, Deendyal Nagar, Kanpur, U.P. - 208 002
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-6203.71761

Rights and Permissions

The purpose of this study was to find out the effect of various physical parameters on the skin and build-up doses of 15-MV photon beams. The effects of field dimensions, acrylic shadow tray, focus to-skin distance (FSD) on surface and buildup dose were determined for open, motorized 60° wedge (MW) and blocked fields. A 'Markus' plane parallel plate chamber was used for these measurements in an Elekta (6-15MV) linear accelerator. The surface dose for MW fields was lower than the dose for an open field, but the trend reversed for large fields and higher degree wedges. With the use of an acrylic shadow tray, the surface dose increased for all field sizes, but the increase was dominant for large fields. The surface dose for blocked fields was lower than the dose for open fields. The percentage depth dose of 10 Χ 10 cm 2 field at surface (PDD0) for open beam were 13.89%, 11.71%, and 10.74% at 80 cm, 100 cm, and 120 cm FSD, respectively. The blocking tray increased PDD0 of 10 Χ 10 cm 2 field to 26.29%, 14.01%, and 11.53%, while the motorized 60° wedge decreased PDD0 to 11.32%, 9.7%, and 8.9 % at these FSDs. The maximum PDD difference seen at surface (i.e., skin) for 5 Χ 5 cm 2 , 15 Χ 15 cm 2 , and 30 Χ 30 cm 2 are 0.5%, 4.6%, and 5.6% for open field and 0.9%, 4.7%, and 7.2% for motorized 60΀ wedge field, when FSDs varied from 80 cm to 120 cm. The maximum PDD difference seen at surface for 5 Χ 5 cm 2 , 15 Χ 15 cm 2 , and 30 Χ 30 cm 2 fields are 5.6%, 22.8%, and 29.6%, respectively, for a 1.0-cm perspex-blocking tray as the FSD is changed. The maximum PDD difference was seen at the surface (i.e., skin) and this decreased with increasing depth.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5387    
    Printed169    
    Emailed1    
    PDF Downloaded352    
    Comments [Add]    

Recommend this journal