Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 1168  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2007  |  Volume : 32  |  Issue : 3  |  Page : 108-117

Evaluation of partial volume effect correction methods for brain positron emission tomography: Quantification and reproducibility


1 Turku PET Centre, University of Turku / Turku University Central Hospital, Turku; Department of Information Technology, University of Turku, Turku, Finland
2 Turku PET Centre, University of Turku / Turku University Central Hospital, Turku, Finland
3 Turku PET Centre, University of Turku / Turku University Central Hospital, Turku; Department of Psychiatry, University of Turku, Turku, Finland
4 Department of Information Technology, University of Turku, Turku, Finland

Correspondence Address:
Merisaari Harri
Department of Information Technology, 20014 University of Turku
Finland
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-6203.35723

Rights and Permissions

Quantitative accuracy of positron emission tomography (PET) is decreased by the partial volume effect (PVE). The PVE correction (PVC) methods proposed by Alfano et al., Rousset et al., Müller-Gδrtner et al. and Meltzer et al. were evaluated in the present study to obtain guidelines for selecting among them. For accuracy evaluation, the Hoffman brain phantom was scanned with three PETs of differing spatial resolution in order to measure the effect of PVC on radioactivity distribution. Test-retest data consisting of duplicate dynamic emission recordings of the dopamine D2-receptor ligand [ 11 C] raclopride obtained in eight healthy control subjects were used to test the correction effect in different regions of interest. The PVC method proposed by Alfano et al. gave the best quantification accuracy in the brain gray matter region. When the effect of PVC on reliability was tested with human data, the method of Meltzer et al. proved to be the most reliable. The method by Alfano et al. may be better for group comparison studies and the method by Meltzer et al. for intra-subject drug-effect studies.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6801    
    Printed228    
    Emailed0    
    PDF Downloaded567    
    Comments [Add]    
    Cited by others 8    

Recommend this journal